Common array manager software.

How to Download Common Array Manager (CAM) Software and Patches [Doc ID 1296274.1] Note - Each array should be managed by one CAM management host only. Installing the management software on more than one host to manage the same array can cause discrepancies in the information reported by CAM.

Common array manager software. Things To Know About Common array manager software.

5. From the Oracle Java Web Console page, select Sun Storage Common Array Manager from the Storage section of the Oracle Java Web Console page. Providing Site Information. When you open the Common Array Manager after a first-time installation, the General Configuration page displays. 1. Enter the required site and contact information for your site.How to Download Common Array Manager (CAM) Software and Patches [Doc ID 1296274.1] Note - Each array should be managed by one CAM management host only. Installing the management software on more than one host to manage the same array can cause discrepancies in the information reported by CAM.Dec 31, 2014 · Software: Common Array Manager, version 6.8.1. License Term: Perpetual (subject to termination under the SLA) Licensed Unit: Software Copy. Licensed unit Count ... Starting the Management Software. The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web-based browser interface is the primary interface for configuring, managing, and monitoring the system. Command-line interfaces options are also ...

Note: The sscs command has an 30 minute inactivity timer before you are logged out. cd /opt/SUNWsesscs/cli/bin/. sscs login -u storage|guest -h host-name [-f] [-t] The following list describes the short and long name command options for the login command: -u, --username. Default user names are storage and guest. The Sun Storage Common Array Manager (CAM) 6.10 Update release is available only for Solaris OS management hosts. Oracle’s Sun Storage Common Array Manager (CAM) 6.10 software that includes the fix for the following CVEs is supported only on Oracle Solaris 10 SPARC and x86 platforms. If you are running the CAM software on Windows or Linux ... 2. Instructions to download Common Array Manager (CAM). Method 1 - Searching with the MOS patch number: Log in to My Oracle Support. Click on the "Patches & Updates" tab on the top bar. In the "Patch Name or Number" field, enter the patch number (ie: 10272123 or 141474-01) corresponding to the CAM software or patch you want to download.

Sun Storage Flexline 380 Array Sun Storage Common Array Manager (CAM) - Version: 5.0 and later [Release: 5.0 and later] ... [TM] Configuration Service or CAM Software., or SANtricity ES Storage Manager Solution Steps to Follow Every volume built on an Sun StorageTek [TM] 6000/25x0 array line has two properties, a "preferred controller" and an ...

Sun Storage Common Array Manager does not provide an SNMP agent that can be queried using SNMP ’GET’ operations. At times, the devices themselves support SNMP ’GET’ operations although all the arrays supported by the array management software at this time do not.This guide can help you with the basic steps of installing Oracle’s Sun Storage Common Array Manager software. If you are upgrading from a previous version or need additional information, see theSun Storage Common Array Manager Software Installation and Setup Guide. See Documentation, Support, and Training for documentation links.Note - For other arrays managed by the Sun StorageTek Common Array Manager, firmware, this release may require special firmware instructions. Refer to the Sun StorageTek Common Array Manager Software Release Notes, Release 6.1.2 (or later) for the latest firmware information and a list of firmware files for your array.The Sun Blade 6000 Disk Module expanders are SES-2 compliant. These enclosure management features are available through the management software, Oracle’s Sun Storage Common Array Manager (CAM), which provides a system administrator with the following capabilities: Event and fault monitoring. E-mail alert notification. FRU …

Common Array Manager (CAM) Software and Patches” Doc ID 1296274.1 available on MOS. Note – Each array should be managed by one CAM management host only. Installing the management software on more than one host to manage the same array can cause discrepancies in the information reported by CAM.

The Sun StorageTek Common Array Manager Installation Software CD provides three installation-related wizards: GUI software installer - Enables you to use a graphical user …

Windows: Uninstall all versions of the Sun StorageTek Configuration Service management software prior to the Common Array Manager 5.1.0.10 release. Later versions do not have to be removed. Check that previously installed services, such as the Storage Automated Diagnostic Environment, are not performing a function on the array over the Ethernet … The Sun StorageTek Common Array Manager software is a web-based management software that provides both a browser interface and a command-line interface (CLI) for configuring and managing arrays on an external management host. Management host platforms can be: Note - Windows XP Home Edition is not supported. To use the Sun Storage Common Array Manager, users and roles must be defined on the host and assigned in the array management software. Make sure the following user names are defined on your systems: ... User names in the array management software must be currently defined users on the host. To add new users to hosts running Solaris or Linux …The Common Array Manager software provides an easy-to-use interface from which you can configure, manage, and monitor Sun StorageTek and Sun Storage arrays. The software includes a distributed architecture which enables you to manage Sun/StorageTek Storage platforms throughout your company, regardless of location. Sun StorageTek Common Array Manager The Sun StorageTek Common Array Manager software is a key component for the initial configuration and operation of the Sun StorageTek 2500 Series Array hardware. It is installed on a management host cabled to the array via out-of-band Ethernet (cables for this connection are provided). To obtain a general ...

“Related Documentation” on page vi for a list of array installation document titles. Related Documentation TABLE P-1 provides a list of documents related to the Sun Storage Common Array Manager software. TABLE P-1 Related Documentation Application Title Latest information Sun Storage Common Array Manager Software Release Notes 1. Use the IP address of the management host to access the management software: https://cam-management-host:6789 2. Log in as root (Solaris OS) or Administrator (Windows). The Oracle Java Web Console page is displayed. Next Steps Go to the Sun Storage Common Array Manager Software Installation and Setup Guideor Online Help for information 快速入门指南. 本指南可帮助您了解 Oracle Sun Storage Common Array Manager 软件的基本安装步骤。. 如果要从先前版本升级或者需要其他信息,请参见《Sun Storage Common Array Manager 安装和设置指南》。. 相关文档链接请参见文档、支持和培训。. This chapter describes two types of complete installation of Common Field Manager software: Off a local senior host; On a central management server These procedures …The Sun StorageTek Common Array Manager software (5.1.3 and above) provides an easy-to-use interface from which you configure, manage, and monitor Sun StorageTek storage systems, including the Sun StorageTek 2500 Series Array. You can also use the Common Array Manager software to diagnose problems, view events, and monitor the …The Sun Blade 6000 Disk Module expanders are SES-2 compliant. These enclosure management features are available through the management software, Oracle’s Sun Storage Common Array Manager (CAM), which provides a system administrator with the following capabilities: Event and fault monitoring. E-mail alert notification. FRU …

Starting the Management Software. The Sun StorageTek Common Array Manager provides a browser interface for accessing the management software from any host that is connected to the site LAN. The web-based browser interface is the primary interface for configuring, managing, and monitoring the system.Prerequisite for Windows Storage Management Stations:If you have an earlier version of storage management software (other than CAM) loaded onto your Windows operating system, uninstall it before using the upgrade utility. The Common Array Manager software is the only supported storage management software for the 2500 Series array.

Predict Your Design. Line Array Calculator (LAC) is a software tool providing two-dimensional acoustic simulation and mechanical validation of flown and ground-deployed VTX Series and SRX900 sound systems. Line Array Calculator’s enhanced acoustical modeling includes color SPL mapping, 0dB Isobar, and SPL attenuation modes with …Sun StorageTek 2500 Series Array Regulatory & Safety Manual. HTML. PDF. Sun Storage Common Array Manager Software 6.10 Documentation. LIBRARY. Sun Storage Common Array Manager Software 6.9 Documentation. LIBRARY. Sun Storage Common Array Manager Software 6.8 Documentation. LIBRARY.The Sun Blade 6000 Disk Module expanders are SES-2 compliant. These enclosure management features are available through the management software, Oracle’s Sun Storage Common Array Manager (CAM), which provides a system administrator with the following capabilities: Event and fault monitoring. E-mail alert notification. FRU …Included with the Sun Storage Common Array Manager installation package and DVD is Microsoft Operations Manager 2005 (MOM), an IT services management tool. MOM is a separate application that integrates with Sun Storage Common Array Manager, and is delivered as a zip file with the other Sun Storage Common Array Manager installation files.Uninstall all versions of the Sun StorageTek Configuration Service management software prior to the Common Array Manager 5.1.0.10 release. Later versions do not have to be removed. 2. Decide on the installation type you want to perform, and go to one of these sections: Installing the Full Management Software; Custom Installation OptionsThe Sun StorageTek Common Array Manager software provides you with an easy-to-use interface to configure, manage, and monitor Sun StorageTek storage systems, including the Sun StorageTek 6140 Array. You can also use the Common Array Manager software to diagnose problems, view events, and monitor the health of your array.Uninstall all versions of the Sun StorageTek Configuration Service management software prior to the Common Array Manager 5.1.0.10 release. Later versions do not have to be removed. 2. Decide on the installation type you want to perform, and go to one of these sections: Installing the Full Management Software; Custom Installation Options 1. Use the IP address of the management host to access the management software: https://cam-management-host:6789 2. Log in as root (Solaris OS) or Administrator (Windows). The Oracle Java Web Console page is displayed. Next Steps Go to the Sun Storage Common Array Manager Software Installation and Setup Guideor Online Help for information

The Sun StorageTek Common Array Manager Installation Software provides three installation-related wizards: GUI software installer - Enables you to use a graphical user interface wizard to install a selection of applications to support a local or remote …

About the Management Software. Oracle’s Sun Storage Common Array Manager (CAM) software is a key component for the initial configuration, operation, and monitoring of Sun Storage 2500-M2 arrays hardware. It is installed on a management host cabled to the array via out-of-band Ethernet. Note: In-band management is also supported.

List the management software application that<br /> you are logged in to.<br /> Modify the management software application<br /> that you are logged into.<br /> Show all of the operating systems that are<br /> supported by the array. The values returned can<br /> be used in subsequent requests to create or<br />Sun StorageTek Common Array Manager Software Release Notes, v6.0.1: HTML: PDF: Sun StorageTek Common Array Manager Software Release Notes, v6.0: HTML: PDF: Sun StorageTek Common Array Manager Software Installation Guide, v6.0: PDF: Sun StorageTek Common Array Manager CLI Quick Reference, v6.0: PDFThis article documents Sun StorageTek 2540 (FC) Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose …Array Manager software provides a comprehensive storage management solution in an integrated, graphical view. From a single location, Array Manager enables you to …Goal. This article documents Sun Storage 6140 Array's components firmware baseline bundled in each corresponding CAM release and patched versions. This document assumes the relevant array product is managed with Common Array Manager. This reference can be used by end-user and all levels of support personnel for purpose of …The "Services" application can be launched in Windows to confirm that the service name "Sun_STK_FMS" (Sun Storage Common Array Manager Fault Management Service) is not running. See the example below: Additionally, the following errors may exist in the file C:\Program Files (x86)\Sun\Common Array … How to Download Common Array Manager (CAM) Software and Patches [Doc ID 1296274.1] Note - Each array should be managed by one CAM management host only. Installing the management software on more than one host to manage the same array can cause discrepancies in the information reported by CAM. Free common array manager download. Development Tools downloads - Sun Storage Common Array Manager Online Help by Oracle Corporation and many more programs... Windows Mac. ... Expression Console software supports probe set summarization and CHP file generation for 3' expression (e....Plus 2.0 Array), ...See the Sun Storage Common Array Manager Software Release Notes for a list of supported operating system platforms. For more information about CLI commands, see the sscs man page and the Sun Storage Common Array Manager CLI Guide. Installing the Administrator Host CLI Software . 1. Start the installation using the steps for your OS. File Name: am360a05.exe. File Size: 39.02 MB. Format Description: This file format consists of an archive of files that may be decompressed to a directory on the hard drive. The installation can then be done from that directory. Download. To ensure the integrity of your download, please verify the checksum value.

The Sun StorageTek Common Array Manager software is a web-based management software that provides both a browser interface and a command-line interface (CLI) for configuring and managing arrays on an external management host. Management host platforms can be: Note - Windows XP Home Edition is not supported. Firmware. Firmware delivered with Sun Storage Common Array Manager software can be installed using the Install Firmware Baseline feature. However, moving from one major firmware release to another might require special procedures.Software Release Notes, Release 6.10 Update for Solaris OS Hosts September 2015 Review important late-breaking information about Sun Storage Common Array Manager 6.10 Update.Instagram:https://instagram. smart callem385globalmappermoviehax The array management software saves the configuration to allow access control between the specified SAS ports and targets. 7. Click Export to save the configuration to a template (see the Online Help for more information about creating SAS Access Configuration templates. ... Sun Storage Common Array Manager saves the current SAS domain ... ramsey classroom comthetvapp. About the Management Software. Oracle’s Sun Storage Common Array Manager (CAM) software is a key component for the initial configuration, operation, and monitoring of Sun Storage 2500-M2 arrays hardware. It is installed on a management host cabled to the array via out-of-band Ethernet. Note: In-band management is also supported. nightowl security Bug fixes that correct previous known software problems. Controller and Disk Firmware Updates. Controller and disk firmware has been updated with this release. See the Sun Storage Common Array Manager Baseline Firmware Reference, Version 6.10 for more information. Service Advisor ASR UpdateSun StorageTek Common Array Manager Software Release Notes, v6.0.1: HTML: PDF: Sun StorageTek Common Array Manager Software Release Notes, v6.0: HTML: PDF: Sun StorageTek Common Array Manager Software Installation Guide, v6.0: PDF: Sun StorageTek Common Array Manager CLI Quick Reference, v6.0: PDF Common Array Manager Software Features. The Sun StorageTek Common Array Manager (CAM) software provides an easy-to-use interface from which you can configure, manage, and monitor Sun StorageTek and Sun Storage arrays. CAM software includes the following: Browser interface Local command line interface Remote command line interface